• Repositorio Institucional Universidad de Pamplona
  • Trabajos de pregrado y especialización
  • Facultad de Ingenierías y Arquitectura
  • Ingeniería Eléctrica
  • Por favor, use este identificador para citar o enlazar este ítem: http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4556
    Título : Indicador de pérdidas técnicas para los niveles de tensión II y III en el Sistema De Distribución Local (SDL) del operador de red Centrales Eléctricas de Norte de Santander (CENS S.A E.S.P.).
    Autor : Leal Miranda, Fabio Enrique.
    Palabras clave : El autor no proporciona la información sobre este ítem.
    Fecha de publicación : 2017
    Editorial : Universidad de Pamplona- Facultad de Ingenierías y Arquitectura.
    Citación : Leal Miranda, F. E. (2017). Indicador de pérdidas técnicas para los niveles de tensión II y III en el Sistema De Distribución Local (SDL) del operador de red Centrales Eléctricas de Norte de Santander (CENS S.A E.S.P.) [Trabajo de Grado Pregrado, Universidad de Pamplona]. Repositorio Hulago Universidad de Pamplona. http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4556
    Resumen : Central electric of North of Santander S.A. E.S.P is a network operator and as such is required to meet certain standards of quality in the provision of services to large and small users. Such obligation is established by entities such as the CREG (energy and Gas Regulatory Commission) and the S.S.P.D (Superintendent for domestic public services), is the main reason why this project arises. In any operator's network (OR) always there are rates of power loss resulting in economic losses and low levels of quality of energy delivered to the users, this forces the OR to pursue strategies that will reduce loss indicators, it is not possible to reduce them in full but if they can be at tolerable levels by the company and which are recognized by the CREG and subsequently paid by the entity. In this project to study and apply the methodology put forward in resolution CREG 019 of 2017 for the calculation of technical losses in tension II and III levels, in order to obtain the indicator of technical losses in the power system of CENS composed lines, transformers, measuring equipment, maneuver and cutting equipment. Will be use of data bases of management of information system (GIS)-based networks and users to determine the topology of circuits, associated equipment, types of users, consumption, among other data, which is pretending the circuits according to the studied methodology software DIGSILENT Power Factory 15.2, and thus obtaining the results that will determine the indicators of losses by circuit and finally the most critical circuits are detected and develop a strategic plan of reduction of technical losses.
    Descripción : El autor no proporciona la información sobre este ítem.
    URI : http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4556
    Aparece en las colecciones: Ingeniería Eléctrica

    Ficheros en este ítem:
    Fichero Descripción Tamaño Formato  
    Leal_2017_TG.pdfLeal_2017_TG2,78 MBAdobe PDFVisualizar/Abrir


    Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.