Por favor, use este identificador para citar o enlazar este ítem:
http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/5295
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Pallares Fragozo, Ciro Alfonso. | - |
dc.date.accessioned | 2022-12-13T13:52:45Z | - |
dc.date.available | 2021-03-17 | - |
dc.date.available | 2022-12-13T13:52:45Z | - |
dc.date.issued | 2021 | - |
dc.identifier.citation | Pallares Fragozo, C. A (2020). Desarrollo de un prototipo de máscara facial electrónica para el monitoreo de la temperatura corporal, respiraciones por minuto y saturación de oxígeno en la sangre de pacientes en observación médica domiciliaria [Trabajo de Grado Pregrado, Universidad de Pamplona]. Repositorio Hulago Universidad de Pamplona. http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/5295 | es_CO |
dc.identifier.uri | http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/5295 | - |
dc.description | Se realizó un sistema de monitoreo electrónico en base a una mascarilla facial electrónica que por medio de seguimiento permite recolectar información acerca de parámetros de oxigenación en la sangre, frecuencia respiratoria y temperatura corporal, este prototipo de mascarilla multisensorial está pensado para el uso de pacientes en observación médica domiciliaria, con intervalos de medida correspondientes a la evaluación médica necesaria consultada a un especialista del sector de la salud.El prototipo aquí desarrollado tiene un sistema embebido Arduino Mega que es capaz de recibir los datos que le envían los sensores por el protocolo I2C y el puerto analógico para posteriormente enviarlo hacia una placa NodeMCU que es capaz de enviar la información recibida, a la nube en firebase para posteriormente visualizarla en un aplicativo móvil, obteniendo así, resultados equiparables a equipos comerciales de bajo costo y validado con un profesional de la salud, además al concluir este prototipo se abren puertas hacia nuevos desarrollos de este tipo de aplicaciones de la salud, posiblemente abriendo tendencia hacia el uso de dispositivos portátiles para diferentes mediciones importantes en materia de diagnóstico o prevención de enfermedades | es_CO |
dc.description.abstract | El autor no proporciona la información sobre este ítem. | es_CO |
dc.format.extent | 134 | es_CO |
dc.format.mimetype | application/pdf | es_CO |
dc.language.iso | es | es_CO |
dc.publisher | Universidad de Pamplona- Facultad de Ingenierías y Arquitectura. | es_CO |
dc.subject | El autor no proporciona la información sobre este ítem. | es_CO |
dc.title | Desarrollo de un prototipo de máscara facial electrónica para el monitoreo de la temperatura corporal, respiraciones por minuto y saturación de oxígeno en la sangre de pacientes en observación médica domiciliaria. | es_CO |
dc.type | http://purl.org/coar/resource_type/c_7a1f | es_CO |
dc.date.accepted | 2020-12-17 | - |
dc.relation.references | E. M. G. Rodrigues, R. Godina, C. M. P. Cabrita, and J. P. S. Catalão, “Experimental low cost reflective type oximeter for wearable health systems,” Biomedical Signal Processing and Control, vol. 31, pp. 419–433, Jan. 2017, doi: 10.1016/j.bspc.2016.09.013. | es_CO |
dc.relation.references | G. R. J. Swennen, L. Pottel, and P. E. Haers, “Custom-made 3D-printed face masks in case of pandemic crisis situations with a lack of commercially available FFP2/3 masks,” International Journal of Oral and Maxillofacial Surgery, vol. 49, no. 5, pp. 673–677, May 2020, doi: 10.1016/j.ijom.2020.03.015. | es_CO |
dc.relation.references | “smart mask | mysite.” https://www.donutrobotics.com/c-mask (accessed Sep. 13, 2020). | es_CO |
dc.relation.references | “Leaf Healthcare.” https://www.leaf.healthcare/ (accessed Sep. 13, 2020). | es_CO |
dc.relation.references | CIVILITY - Next Gen Transparent Mask | Indiegogo.” https://www.indiegogo.com/projects/civility-next-gen-transparent mask?fbclid=IwAR0Kkgtn8Nsgf4VIyCt4ipIzz4fKQ9KASpWUtR9oRWmvdSc WzEiFzv64weY#/ (accessed Sep. 13, 2020). | es_CO |
dc.relation.references | “Inicio - Dispositivo de protección para el personal de la salud.” https://www.easy-co.org/ (accessed Sep. 13, 2020). | es_CO |
dc.relation.references | O. O. Fadare and E. D. Okoffo, “Covid-19 face masks: A potential source of microplastic fibers in the environment,” Science of the Total Environment, vol. 737, Oct. 2020, doi: 10.1016/j.scitotenv.2020.140279. | es_CO |
dc.relation.references | S. Jia, G. Guo, and Z. Xu, “A survey on 3D mask presentation attack detection and ,” Pattern Recognition, vol. 98, Feb. 2020, doi: 101 10.1016/j.patcog.2019.107032. | es_CO |
dc.relation.references | G. R. J. Swennen, L. Pottel, and P. E. Haers, “Custom-made 3D-printed face masks in case of pandemic crisis situations with a lack of commercially available FFP2/3 masks,” International Journal of Oral and Maxillofacial Surgery, vol. 49, no. 5, pp. 673–677, May 2020, doi: 10.1016/j.ijom.2020.03.015. | es_CO |
dc.relation.references | D. Wang et al., “Can Masks Be Reused After Hot Water Decontamination During the COVID-19 Pandemic?,” Engineering, 2020, doi: 10.1016/j.eng.2020.05.016. | es_CO |
dc.relation.references | “CLIU Mask - N99, BIO, Antimicrobial & A.C. Filters.” https://cliu.it/es/ (accessed Sep. 07, 2020). | es_CO |
dc.relation.references | F. Torres and C. Fernández, “Sensores y detectores,” Automática, Robótica y Visión Artificial, p. 63, 2014. | es_CO |
dc.relation.references | Drägerwerk AG & Co. KGaA, “La importancia de la temperatura corporal central Fisiopatología y métodos de medición,” p. 60, 2018. | es_CO |
dc.relation.references | N. C. Dario Londoño Trujillo. MD, MSc, Rafael Acero Colmenraes, auderyPiotrostanalky, “Uso E Interpretación Pulso,” Colombia. Ministerio de Salud y Protección Social de salud colombia, vol. Convenio 5, pp. 6–13, 2016, [Online]. Available: https://www.minsalud.gov.co/sites/rid/Lists/BibliotecaDigital/RIDE/VS/PP/ENT/uso interprtn-oximetria-pulso.pdf. | es_CO |
dc.relation.references | J. J. Talamas Márquez, “Habilidades Básicas III Toma de signos vitales,” Universidad Juarez del Estado de Durango, vol. 1, no. 1, p. 14, 2016, [Online]. Available: http://famen.ujed.mx/doc/manual-de-practicas/a 2016/03_Prac_01.pdf | es_CO |
dc.relation.references | A. E. Pérez, “Diseño de aplicación móvil para la comunicación inalámbrica de señales audiovisuales,” p. 4, 2013 | es_CO |
dc.relation.references | A. E. Pérez, “Diseño de aplicación móvil para la comunicación inalámbrica de señales audiovisuales,” p. 4, 2013. | es_CO |
dc.relation.references | A. Flores, “Sistema electrónico de comunicación paciente-personal,” 2015. | es_CO |
dc.relation.references | I. T. de Queretaro., “Comunicaciones Digitales:Protocolos seriales (uC) ¿Qué es la comunicación serial ?,” 2019. | es_CO |
dc.relation.references | A. Uno and I. M. C. I. Ltda., “Comunicación Serial. | es_CO |
dc.relation.references | M. Araya, “Sensores De Temperatura: Sensores De Temperatura,” April 27, 2015, pp. 4–5, 2015, [Online]. Available: http://snsoresdetemperatura.blogspot.com/2009/05/sensores-de temperatura.html. | es_CO |
dc.relation.references | J. Blum, “ The I 2 C Bus ,” Exploring Arduino®, no. October, pp. 199–221, 2019, doi: 10.1002/9781119405320.ch10. | es_CO |
dc.relation.references | D. Wang et al., “Can Masks Be Reused After Hot Water Decontamination During the COVID-19 Pandemic?,” Engineering, 2020, doi: 10.1016/j.eng.2020.05.016 | es_CO |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | es_CO |
dc.type.coarversion | http://purl.org/coar/resource_type/c_2df8fbb1 | es_CO |
Aparece en las colecciones: | Ingeniería Electrónica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Pallares_2020_TG.pdf | Pallares_2020_TG | 4,88 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.