    dc.contributor.authorBarrios De Avila, Alexander David.-
    dc.date.accessioned2022-11-17T21:31:36Z-
    dc.date.available2018-03-19-
    dc.date.available2022-11-17T21:31:36Z-
    dc.date.issued2018-
    dc.identifier.citationBarrios De Ávila, A. D. (2017). Diseño del sistema de distribución en media tensión zaragocilla 4 de Electricaribe S.A. [Trabajo de Grado Pregrado, Universidad de Pamplona]. Repositorio Hulago Universidad de Pamplona.http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4544es_CO
    dc.identifier.urihttp://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4544-
    dc.descriptionPara resolver los múltiples problemas que presenta el circuito Zaragocilla 4 de la empresa electricaribe S.A. E.S.P en la ciudad de Cartagena de Indias D.T. y C El levantamiento se llevó a cabo en dos fases, la primera se realizó con el objetivo de identificar fallas visibles, tales como; apoyos en mal estado, distancias de seguridad, mal estado en los conductores, estado de los DPS y fusibles, estado de los transformadores, entre otras. La segunda fase, se llevó a cabo analizando los datos de la carga del circuito para el que fue diseñado y su carga actual, y los indicadores de continuidad del servicio al usuario. Lo anterior, con el propósito de generar las actividades (o actuaciones) en las cuales se basará el nuevo diseño del circuito. Durante la segunda fase del proyecto, se evidenció el aumento de la carga, superando la carga proyectada por el diseño inicial, esto, sumado con la falta de inversión de la empresa han generado el mal servicio prestado en este circuito en particular que ha dejado pérdidas económicas altas tanto para los usuarios como para el operador de red. Por eso se han realizado todos los cálculos correspondientes a los conductores, apoyos, crucetas, puesta a tierra, protecciones y alumbrado público. Se diseñó el circuito en mención con el fin de brindar la mayor fiabilidad posible del servicio y por ende generando más ingresos a la empresa y menos descontento entre los usuarios que alimentan las redes del circuito en media tensión. Se reconducirá la trayectoria del circuito para poder organizar las derivaciones y distribuir las cargas que actualmente se encuentran conectadas a este circuito; se ampliarán los tramos y diseñarán todas las derivaciones que conforman el circuito completo Zaragocilla 4, permitiendo la transferencia de carga hacia los circuitos Bosque 4 y viceversa.es_CO
    dc.description.abstractTo solve the multiple problems presented by the circuit Zaragocilla 4 of the company electricaribe S.A. E.S.P in the city of Cartagena de Indias D.T. and C The survey was carried out in two phases, the first was carried out with the objective of identifying visible faults, such as; props in poor condition, safety distances, poor condition of the drivers, state of the DPS and fuses, state of the transformers, among others. The second phase was carried out by analyzing the data of the load of the circuit for which it was designed and its current load, and the continuity indicators of the service to the user. The above, with the purpose of generating the activities (or actions) on which the new design of the circuit will be based. During the second phase of the project, the increase in load was evidenced, surpassing the load projected by the initial design, this, added with the lack of investment of the company, have generated the bad service rendered in this particular circuit that has left losses high economic costs for both users and the network operator. For this reason, all the calculations corresponding to the conductors, supports, crossheads, earthing, protections and public lighting have been made. The circuit was designed in order to provide the highest possible reliability of the service and therefore generating more revenue for the company and less discontent among the users who supply the networks of the medium voltage circuit.es_CO
    dc.format.extent98es_CO
    dc.format.mimetypeapplication/pdfes_CO
    dc.language.isoeses_CO
    dc.publisherUniversidad de Pamplona- Facultad de Ingenierías y Arquitectura.es_CO
    dc.subjectEl autor no proporciona la información sobre este ítem.es_CO
    dc.titleDiseño del sistema de distribución en media tensión Zaragocilla 4 de Electricaribe S.A.es_CO
    dc.typehttp://purl.org/coar/resource_type/c_7a1fes_CO
    dc.date.accepted2017-12-19-
    dc.relation.references13, M. R. (2012). MIE RAT articulo 13.es_CO
    dc.relation.referencesELECTRICARIBE S.A. E.S.P. GAS NATURAL FENOSA. (2014). LÍNEAS AÉREAS DE MEDIA TENSIÓN SIN NEUTRO. CARTAGENA DE INDIAS.es_CO
    dc.relation.referencesENDESA, C. (2016). Calculo de corrientes de corto circuito en baja tension. santiago de Chile.es_CO
    dc.relation.referencesIEE 242-2001, I. s. (2014). Protection and coordination of industrial and commercial power systems.es_CO
    dc.relation.referencesMINISTERIO DE MINAS Y TRANSPORTE. (2015). RETILAP- REGLAMENTO TÉCNICO DE INSTALACIONES Y ALUMBRADO PÚBLICO. En M. D. TRANSPORTE, RETILAP- REGLAMENTO TÉCNICO DE INSTALACIONES Y ALUMBRADO PÚBLICOes_CO
    dc.relation.referencesNEC, N. e. (2011). National Fire Protection Association (NFPA). Las Vegas, Nevada. USA.es_CO
    dc.relation.referencesS.A., C. E. (2007). calculo de corrientes de corto circuito en baja tension.es_CO
    dc.relation.referencessanchez, W. (2016). LINEAS AEREAS DE MEDIA TENSION SIN NEURO.es_CO
    dc.relation.referencestransporte, m. d. (2009). REGLAMENTO TECNICO DE ILUMINACION Y ALUMBRADO PUBLICO.es_CO
    dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2es_CO
    dc.type.coarversionhttp://purl.org/coar/resource_type/c_2df8fbb1es_CO
    Aparece en las colecciones: Ingeniería Eléctrica

    Ficheros en este ítem:
    Fichero Descripción Tamaño Formato  
    Barrios_2017_TG.pdfBarrios_2017_TG3,35 MBAdobe PDFVisualizar/Abrir


    Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.