• Repositorio Institucional Universidad de Pamplona
  • Trabajos de pregrado y especialización
  • Facultad de Ingenierías y Arquitectura
  • Ingeniería Mecatrónica
  • Por favor, use este identificador para citar o enlazar este ítem: http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4520
    Registro completo de metadatos
    Campo DC Valor Lengua/Idioma
    dc.contributor.authorLeal Gafaro, Yessenia Catherine.-
    dc.date.accessioned2022-11-17T15:17:58Z-
    dc.date.available2021-10-07-
    dc.date.available2022-11-17T15:17:58Z-
    dc.date.issued2022-
    dc.identifier.citationLeal Gafaro, Y. C. (2021). Diseño y construcción de un prototipo mecatrónico para rehabilitación pasiva en flexión-extensión y pronación-supinación de antebrazo [Trabajo de Grado Pregrado, Universidad de Pamplona]. Repositorio Hulago Universidad de Pamplona. http://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4520es_CO
    dc.identifier.urihttp://repositoriodspace.unipamplona.edu.co/jspui/handle/20.500.12744/4520-
    dc.descriptionLas enfermedades musculo esqueléticas afectan a los músculos, huesos, articulaciones y tejidos asociados como tendones y ligamentos. Este tipo de lesiones no solo afectan a personas mayores, pueden presentarse en cualquier momento de la vida ya sea por movimientos repetitivos o casos más graves como lesiones por accidentes que generan algún tipo de fractura. En muchos de los casos para ser tratadas estas lesiones se requiere una intervención quirúrgica y de un proceso de rehabilitación. El objetivo de la terapia de rehabilitación es restablecer la función completa para una o más partes del cuerpo, existen factores externos que afecta negativamente el proceso de rehabilitación como son, la disponibilidad del especialista, fallos o falta de equipos a utilizar en el proceso, dificultades en el trasporte del paciente para llegar al lugar de rehabilitación. Como consecuencia de estos factores se incrementan el costo de las terapias, se presenta deserción en los pacientes, rehabilitaciones incompletas o mal hechas, y esto afecta negativamente la enfermedad o lesión del paciente. En el presente trabajo se plantea un prototipo mecatrónico para la rehabilitación pasiva de antebrazo que consiga realizar rutinas de rehabilitación de movimientos flexión-extensión y pronación-supinación permitiendo replicar las condiciones biomecánicas para un proceso eficiente y de esta manera garantizar la restauración total del movimiento. Se halla el modelo cinemático del dispositivo de rehabilitación, realizando el análisis de posición, velocidad y aceleración de cada uno de los elementos de nuestro prototipo sin considerar la fuerza que causa nuestros movimientos. Este prototipo será utilizado una vez el paciente supere la fase de inmovilización y pueda comenzar a realizar los movimientos. Para garantizar que el prototipo permita emular los movimientos flexión-extensión y pronación-supinación se diseña la estructura mecánica cumpliendo con los parámetros establecidos por el análisis de la cinemática y el análisis de síntesis de mecanismos. Cabe señalar que una vez obtenida la estructura del prototipo se prosigue a simular de modo que se pueda comprobar de manera gráfica que nuestro prototipo realice automáticamente los movimientos planteados inicialmente. Una vez realizada la simulación, se procede a la construcción del prototipo teniendo en cuenta todas las condiciones de diseño, seleccionando materiales, diseños de PCB, respectiva programación, ensamble final del dispositivo, por último, pruebas y presentación del dispositivo.es_CO
    dc.description.abstractMusculoskeletal diseases affect the muscles, bones, joints, and associated tissues such as tendons and ligaments. These types of injuries not only affect older people, they can occur at any time in life either due to repetitive movements or more serious cases such as injuries from accidents that generate some type of fracture. In many cases, these injuries require surgical intervention and a rehabilitation process to be treated. The objective of rehabilitation therapy is to restore full function for one or more parts of the body, there are external factors that negatively affect the rehabilitation process such as the availability of the specialist, failures or lack of equipment to use in the process, difficulties in the transport of the patient to reach the rehabilitation site. As a consequence of these factors, the cost of therapies increases, patients drop out, incomplete or poorly done rehabilitations, and this negatively affects the patient's illness or injury. In the present work, a mechatronic prototype for passive forearm rehabilitation is proposed that manages to carry out rehabilitation routines of flexion-extension and pronation-supination movements, allowing the replication of biomechanical conditions for an efficient process and thus guaranteeing total restoration of movement. The kinematic model of the rehabilitation device is found, performing the analysis of position, speed and acceleration of each of the elements of our prototype without considering the force that causes our movements. This prototype will be used once the patient passes the immobilization phase and can begin to perform the movements. To ensure that the prototype allows the emulation of flexion-extension and pronation-supination movements, the mechanical structure is designed complying with the parameters established by the analysis of the kinematics and the analysis of synthesis of mechanisms. It should be noted that once the structure of the prototype is obtained, it continues to simulate so that it can be graphically verified that our prototype automatically performs the initially proposed movements. Once the simulation has been carried out, the prototype is built taking into account all the design conditions, selecting materials, PCB designs, respective programming, final assembly of the device and finally testing and presentation of the device.es_CO
    dc.format.extent123es_CO
    dc.format.mimetypeapplication/pdfes_CO
    dc.language.isoeses_CO
    dc.publisherUniversidad de Pamplona- Facultad de Ingenierías y Arquitectura.es_CO
    dc.subjectLa autora no proporciona la información sobre este ítem.es_CO
    dc.titleDiseño y construcción de un prototipo mecatrónico para rehabilitación pasiva en flexión-extensión y pronación-supinación de antebrazo.es_CO
    dc.typehttp://purl.org/coar/resource_type/c_7a1fes_CO
    dc.date.accepted2021-07-07-
    dc.relation.referencesAngulo, T., Alvarez, A., & Fuentes, Y. (2011). Biomecánica clínica, Biomecánica de la extremidad superior, Exploración del hombr. Reduca, 1.es_CO
    dc.relation.referencesApuntes libra. (2014). Anatomia miembro superior 2.es_CO
    dc.relation.referencesAvila, R., Prado, L., & González, E. (2007). Dimensiones antropométricas de población latinoamericana.es_CO
    dc.relation.referencesBeltrán, J. C. (2008). Identificación de las personas con discapacidad en los territorios desde el rediseño del registro.es_CO
    dc.relation.referencesD'Freitas, N. A. (2016). Complejo Articular del Codo: Biomec·nica. Revista de la Sociedad Venezolana de Ciencias MorfolÛgicas, 46.es_CO
    dc.relation.referencesFundación once. (2007). II C ongreso internacional sobre Robótica, Domótica, y teleasistencia para todos.es_CO
    dc.relation.referencesGuzman, D. E., & Londoño, J. (2016). Rehabilitación de miembro superior con ambientes virtuales: revisión. Scielo, 1-2.es_CO
    dc.relation.referencesKapandji, A. (2006). Fisiología articular. Madrid: Medica Panamericana.es_CO
    dc.relation.referencesMaría Guadalupe Contreras Calderón, E. C. (2019). Mecanismo de pronosupinación adaptable a dispositivos de rehabilitación de la extremidad superior. Revista UIS Ingenierías, 89-90.es_CO
    dc.relation.referencesMendez, D. S., Montiel, M. A., & Gonzalez, E. L. (2017). Design of an Exoskeleton Prototype for Shoulder Rehabilitation. SciELO Analytics, 2.es_CO
    dc.relation.referencesMoore, K., Dalley, A., & Agur, A. (2007). Anatomia con orientación clinica.es_CO
    dc.relation.referencesMyomo. (2012). Informe de exesqueleto. Obtenido de https://exoskeletonreport.com/product/myopro/es_CO
    dc.relation.referencesNariño, R., Alonso, A., & Hernández, A. (2016). Antropometría. Análisis comparativo de las tecnologías para la captación de las dimensiones antropometrícas. 48-49.es_CO
    dc.relation.referencesOrganización mundial de la salud, M. C. (2011). Resumen informe mundial sobre la discapacidad.es_CO
    dc.relation.referencesPehlivan, A. U., & Pehlivan, K. (2019). Houston Bionics. Obtenido de https://www.houstonbionics.com/exorehab-xes_CO
    dc.relation.referencesRichardson, R., Brownb, M., Bhakta, B., & Levesly, M. (2005). Impedance control for a pneumatic robot based around pole-placement,joint space controllers. Elsevier, 2.es_CO
    dc.relation.referencesSanchez, B. d., Montiel, M. A., & Gonazales, E. L. (2018). Diseño y Construcción de un Prototipo de Exoesqueleto para Rehabilitación de hombro. SOMIB sociedad Mexicana de Ingenieria Biomedica, 1.es_CO
    dc.relation.referencesSugar, T. (2007). Diseño y control de RUPERT: un dispositivo para la terapia repetitiva robótica de las extremidades superiores. IEEE explore, 8es_CO
    dc.relation.referencesThomson, E. A. (7 de junio de 2000). Mit news on campus and around the word. Obtenido de https://news.mit.edu/2000/manus-0607es_CO
    dc.relation.referencesValdivia, C. H., Ortega, A. B., & Salazar, M. O. (2013). Entendiendo la mecatronica en rehabilitación. CIINDET , 3es_CO
    dc.relation.referencesYin, M., & Agrawal, S. (2012). Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation. IEEE, 2-3.es_CO
    dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2es_CO
    dc.type.coarversionhttp://purl.org/coar/resource_type/c_2df8fbb1es_CO
    Aparece en las colecciones: Ingeniería Mecatrónica

    Ficheros en este ítem:
    Fichero Descripción Tamaño Formato  
    Leal_2021_TG.pdfLeal_2021_TG3,41 MBAdobe PDFVisualizar/Abrir


    Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.